SPARC S7-2 Server

发布时间:2024-12-11 内容来源:网络

SPARC S7-2 Server

SPARC_S7_2_front_zoom.jpg


Processor
NumberOne or two SPARC S7 8-Core, 4.27GHz processors, not expandable
CPUs
  • Up to 64 threads per processor (up to 8 threads per core)
  • Four data analytics accelerators per processor, each supporting four concurrent in-memory query operations with decompression
  • Eight on-chip encrytion instruction accelerators with direct nonpriviledged support for 15 industry-standard cryptographic algorithms: AES, Camellia, CRC32c, DES, 3DES, DH, DSA, ECC, MD5, RSA, SHA-1, SHA-224, SHA-256, SHA-384, SHA-512 (one per core)
  • Eight floating-point units per processor (one per core)
  • One random number generator (one per processor)
Cache memoryLevel 1: 16KB instruction and 16 KB data per core
Level 2: 256 KB L2 I$ per four cores, 256 KB L2 D$ per core pair
Level 3: 16 MB L3$ on chip
Main Memory
Capacities
  • DIMM slots: 8 slots per processor, supporting half or fully populated configurations
  • DIMM type: DDR4-2400
  • DIMM size: 16GB, 32GB or 64GB
  • Maximum capacity: 1024GB max configuration with 64GB DIMMs and two processors
Standard Integrated Interfaces
Network4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating
Network ManagementOne dedicated 10Mbps/100Mbps/1Gbps RJ-45 port Ethernet port
Serial ManagementOne dedicated RJ-45 port
Remote ManagementIntegrated Lights Out Manager (ILOM)
USBTwo USB 2.0 ports (front)
PCI Expansion Slots
  • 3 low-profile PCI-Express 3.0 x8 slots.
Slot #PhysicalElectrical
1x16x8
2x16x8
3x8x8
Internal Mass Storage
Disks
  • 1x optional 12Gbps SAS-3 controller
  • Eight 2.5-inch SAS-3 disk drive slots (4 support NVMe)
  • 600GB or 1.2TB 2.5-inch SAS-3 disk drives
  • 400GB 2.5-inch SAS-3 solid state drives
  • 800GB 2.5-inch SAS-3 solid state drives
  • 1.6TB or 3.2TB or 6.4TB NVMe solid state drives
  • SAS-3 / NVMe mixing is supported.
Power Supplies
2 × 800 or 1200 Watt, hot-swappable, N+1 redundant power supply units (PSU)
Environment
Input Voltage100 to 120 VAC at 800W, 50/60Hz
200 to 240 VAC at 1200W, 50-60Hz
Input Current4.1/8.6 A @ 100/200 VAC (max)
Input Power851/819 W @ 100/200 VAC (max)
Maximum Heat Dissipation2904 BTU/hr, 3064 KJ/hr
Power ConsumptionOnline power calculator
Temperature

Operating: 5° C to 35° C (41° F to 95° F) ; decrease in maximum temperature: above 900 M (2952 ft) 1° C/300 m (1.8°/984 ft)
Nonoperating: -40° C to 65° C (-40° F to 149° F)

HumidityOperating: 10% to 90% relative humidity noncondensing, 27° C (81° F) maximum dew point
Nonoperating: 93% relative humidity noncondensing, 38° C (100° F) maximum wet bulb
Altitude

Operating: 0m to 3,000m (0 ft. to 9,840 ft), except in China markets where regulations may limit installations to a maximum altitude of 2000 m
Nonoperating: 0m to 12,000m ( 0 ft. to 39,370 ft.)

Acoustic Noise - Sound Power Level LwAD60% Fan Speed: 7.7 B (1 B = 10 dB)
100% Fan Speed: 8.6 B (1 B = 10 dB)
Acoustic Noise - Sound Pressure LpAM60% Fan Speed: 62 dBA (avg of four bystander positions)
100% Fan Speed: 72 dBA (avg of four bystander positions)
Regulations
Meets or exceeds the following requirements:
SafetyUL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all country differences
EMI/EMCFCC 47 CFR 15, ICES-003, EN 55022, EN61000-3-2, EN61000-3-3
ImmunityEN 55024
CertificationsNorth American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India), BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP (Korea), VCCI (Japan), VNTA (Vietnam), Morocco, Republic of Srpska.
European Union DirectivesRestriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and WEEE Directive 2012/19/EU
Dimensions and Weight
Height43 mm (1.7 in.), 1U
Width437 mm (17.2 in.)
Depth737 mm (29 in.)
Weight18 kg (40 lbs) max, without rackmount kit
Clearance and Service Access
Front1232 mm (48.5 in.)
Rear914.4 mm (36 in.)